Preamble and SFD

Duration: 3 min

This video lesson is available to enrolled students.

Return to /learn/NIACL-AO-IT-SPECIALIST/data-communication-networking-it-specialist/data-link-layer-ethernet/ethernet-frame-format-preamble-sfd/asset-preamble-and-sfd after enrolling

Inside: a video lesson and guided study material.

Module outline

  1. Quantitative Aptitude: Ratio and Proportion (Ratios), Data Interpretation, Mixture and Alligation, Permutation and Combination, Number System, Sequence and Series (Series), Speed Time and Distance, Speed Mathematics and Basic Mathematics, Algebra, Percentage, Profit and Loss, Simple Interest and Compound Interest, Powers and Exponents (Surds and Indices), Time and Work, Mensuration and Geometry, Partnership
  2. Reasoning Ability: Series (Number and Letter Series) (Numerical Relations and Reasoning), Coding Decoding, Data Sufficiency, Seating Arrangements, Deductive and Inductive Reasoning (Logical Deduction and Induction) (Prepositional Reasoning), Directions (Direction Test), Ranking, Order and Sequence, Syllogisms, Blood Relations, Puzzle Solving (Puzzles), Inequality, Machine Input-Output
  3. English Language: Vocabulary, Noun, Subject Verb Agreement (Verb Noun Agreement), Adjectives, Tenses, Comprehension / Reading Comprehension / Unseen Passages (Critical Reasoning) (Paragraph Questions), Cloze Test (Cloze Passage), Sentence Correction (Error Correction), Sentence Completion (Fill in the blanks), Sentence Re-arrangements (Para Jumbles) (Narrative Sequencing), Sentence Construction, Pronoun, Preposition, Conjunction, Adverb, Verb, Modals, Articles, Determiner, Interjection
  4. General Awareness: Evolution of Indian Banking (Banking & Financial Awareness), GK- Current Affairs, Static General Knowledge, Indian Economy
  5. C Concepts + MCQs (IT Specialist): C Programming by Yash Sir, C Language Core
  6. Java (IT Specialist): Java
  7. Python (IT Specialist): Python for Placements by Yash Sir, Python Basics
  8. OOPs (IT Specialist): Object Oriented Programming (OOPS)
  9. DBMS (IT Specialist): Basics of DBMS, ER Diagram, Relational Model & Functional Dependencies, Keys & Integrity Constraints, Normalization (1NF - BCNF), Decomposition Properties & 4NF, File Organization & Indexing, Relational Algebra, Relational Calculus, Transaction Management, Concurrency Control, Database Recovery, ORDBMS, Database Security & Authorization, Query Processing & Optimization, Enhanced Data Models, Data Warehousing & Mining, Big Data Systems, NoSQL
  10. SQL (IT Specialist): SQL
  11. Software Engineering (IT Specialist): Fundamentals of Software Engineering, Software Requirements and Quality Assurance, Software Design, Estimation and Metrics, Software Testing, Software Maintenance and Configuration Management
  12. Data Structure (IT Specialist): Introduction to DS, Array, Stack, Queue, Linked List, Tree, Graphs, Hashing
  13. Operating System (IT Specialist): Introduction to OS, Process Management, CPU Scheduling, Process Synchronization, Deadlock, Threads & Process Creation, Memory Management, Virtual Memory, Disc Scheduling, File Management, Windows OS, Linux OS, Security, Distributed Systems, Virtual Machines
  14. Compiler Design (IT Specialist): Intro to Compilers, Lexical Analysis, Grammar & CFG, Syntax Analysis: Top-Down, Syntax Analysis: Bottom-Up, Semantic Analysis & SDT, Intermediate Code Gen, Code Optimization, Run Time Environment
  15. Computer Architecture (IT Specialist): Basics of COA, Floating Point Rep, Cache Memory Organization, Input Output Organisation, Pipelining, Instr Formats & Modes, Control Unit Design, Register Transfer and Microoperations, Multiprocessors, Programming the Basic Computer
  16. Data Communication & Networking (IT Specialist): Introduction to CN, Data Communication, DLL: Access Control, DLL: Flow Control, DLL: Error Control, DLL: Framing, Data Link Layer - Ethernet, Net Layer: IPv4 & Proto, Net Layer: IP Addressing, Net Layer:Routing Protocol, Transport Layer Services, TL: Congestion & UDP, Application Layer, Hardware basics, Network Security
  17. Descriptive Test (Main Exam): English Writing Ability
AI summary & chapters

AI Summary

An AI-generated summary of this video lecture.

This short lecture segment introduces the Preamble and Start Frame Delimiter (SFD) fields of an Ethernet frame. The instructor presents a slide titled “Preamble,” defining it as a 7-byte field containing alternating 0s and 1s, equivalent to 56 bits. The slide notes that the Preamble is added at the physical layer and serves synchronization purposes. An Ethernet frame diagram labels the fields in order: Preamble (7 bytes), SFD (1 byte), Destination address (6 bytes), Source address (6 bytes), Length (2 bytes), Data and padding, and CRC (4 bytes). The instructor circles the Destination and Source address fields. On-screen notes also mention minimum payload length of 46 bytes, maximum payload length of 1500 bytes, and minimum frame length of 512 bits or 64 bytes. The lesson then transitions to the SFD slide, stating that it is a 1-byte field always set to 10101011, with the final two bits “11” marking the beginning of the frame. The SFD is also added at the physical layer, and a note indicates that historically only the SFD existed before the Preamble was added later.

Chapters

  1. 0:00 – 2:00 00:00-02:00

    The slide titled “Preamble” defines the field as a 7-byte sequence of alternating 0s and 1s, shown on-screen as “Preamble: 56 bits of alternating 1s and 0s.” The instructor explains that the Preamble is added at the physical layer for synchronization. An Ethernet frame diagram displays labeled blocks: Preamble (7 bytes), SFD (1 byte), Destination address (6 bytes), Source address (6 bytes), Length (2 bytes), Data and padding, and CRC (4 bytes). Handwritten ovals circle the Destination and Source address fields. Additional on-screen notes state minimum payload length 46 bytes, maximum payload length 1500 bytes, and minimum frame length 512 bits or 64 bytes.

  2. 2:00 – 2:53 02:00-02:53

    The presentation switches to a slide titled “Start Frame Delimiter (SFD),” which states that the SFD is a 1-byte field always set to “10101011.” The slide highlights that the last two bits, “11,” mark the beginning of the frame and that the SFD is added at the physical layer. A note below reads “only SFD was there Preamble was added later,” indicating the historical development of these fields. The instructor gestures while explaining, and the frame diagram remains visible with Preamble labeled as 7 bytes and SFD as 1 byte.

The central teaching point is the structure and purpose of the Preamble and SFD in Ethernet framing. The Preamble provides synchronization through a 7-byte alternating bit pattern, while the SFD signals frame start with its fixed value 10101011, where the trailing “11” distinguishes it from the alternating pattern. Both fields are physical-layer additions, and the diagram situates them before the data-link layer addresses and payload. The historical note that SFD preceded Preamble adds context for why both exist.

Loading lesson…